skip to Main Content

Rohde & Schwarz ESR7 EMI Test Receiver, 9 kHz to 7 GHz

$89,990.00

Rated 0 out of 5
(be the first to review)
Add to Wishlist
Add to Wishlist

Categories: ,

Description

The R&S ESR7 EMI Test Receiver is a dual instrument that measures electromagnetic disturbances while simultaneously functioning as a fully featured, powerful signal and spectrum analyzer for lab applications.  Rapid-fire-speed measuring occurs by the instrument’s use of an FFT-based time domain scan and detailed analysis and history of disturbance signals is accomplished by realtime spectrum analysis using a wide variety of diagnostic tools. This robust and compact, dual instrument is user friendly with its straightforward display, intuitive touchscreen interface.

Features and Specifications:

  • Features

    • EMI test receiver and signal/spectrum analyzer combined in a single instrument
    • Compliant with CISPR 16-1-1 Ed. 3.1
    • Preselection with integrated 20 dB preamplifier
    • Ultra-fast time domain scan in addition to conventional stepped frequency scan
    • Realtime spectrum analysis with up to 40 MHz span for detailed investigation of disturbance signals
    • Powerful measurement and analysis functions in frequency and time domain
    • Time domain display with high resolution (50 μs)
    • Automatic test routines
    • Convenient operation, straightforward display
    • Robust and compact – ideal for the mobile use
  • Specifications

    • Frequency
      • Frequency Range:  9 kHz to 7 GHz
    • Level
      • Max RF level (CW):
        • RF attenuation ≥ 10 dB; RF preamplifier off:  30 dBm (= 1 W)
        • RF attenuation ≥ 10 dB; RF preamplifier on:  23 dBm (= 0.2 W)
      • Max Pulse Voltage:
        • RF attenuation ≥ 10 dB:
          • Input 1:  150 V
          • Input 2:  450 V
      • Max Pulse Energy:
        • RF attenuation ≥ 10 dB; 10 μs
          • Input 1:  1 mWs
          • Input 2:   20 mWs
      • 1 dB Compression:
        • RF attenuation 0 dB; RF preamplifier and preselection off:  +3 dBm, nominal
    • IF and Resolution Bandwiths
      • Analyzer Mode (span ≥ 10 Hz) and Receiver Mode: 10 Hz to10 MHz (–3 dB) in 1/2/3/5/10 steps
      • Analyzer and Receiver Mode: 200 Hz, 9 kHz, 120 kHz (–6 dB), 1 MHz (impulse bandwidth)
      • Preselection:
        • Can be switched off in analyzer mode:  16 Fixed Filters
      • Preamplifier:
        • Can be switched on/off:  1 kHz to 7 GHz, 20 dB gain, nominal
      • Measurement Time:
        • Analyzer Mode (Sweep Time):
          • span = 0 Hz: 1 μs to 16 000 s
          • span ≥ 10 Hz (swept): 1 ms to 16 000 s
          • span ≥ 10 Hz (FFT): 7 μs to 16 000 s
        • Receiver Mode (Stepped Frequency Scan):  50 μs to 100 s (per frequency)
        • Receiver Mode (Time Domain Scan):  50 μs to 100 s (per frequency subrange)
      • Frequency Step Size:
        • Receiver Mode (Stepped Frequency Scan):  min. 1 Hz
        • Receiver Mode (Time Domain Scan):  0.25 × IF bandwidth
    • Detectors
      • Receiver Mode:
        • maximum peak
        • minimum peak
        • quasi-peak
        • RMS
        • average
        • average with meter time constant (CISPR average)
        • RMS average (CISPR-RMS)
    • Displayed Average Noise Level (DANL)
      • Receiver Mode, Nominal, Average Detector (AV), RF Attenuation 0 dB, Termination 50 Ω:
        • Preamplifier Off:
          • 500 MHz, bandwidth 120 kHz:  < 6 dBμV
          • 3 GHz, bandwidth 1 MHz:  < 17 dBμV
        • Preamplifier On:
          • 500 MHz, bandwidth 120 kHz:  < –7 dBμV
          • 3 GHz, bandwidth 1 MHz:  < 5 dBμV
    • Number of Sweep (Trace) Points
      • Analyzer Mode (Standard):  101 to 32 001
      • Analyzer Mode (EMI):  101 to 200 001
      • Receiver Mode:  Max 4 000 000
      • Realtime Analyzer (Option):  801
    • Total Measurement Uncertainty
      • CW signal, level 0 dB to –70 dB below reference level, S/N > 20 dB, auto sweep time,            RF attenuation 10 dB, 20 dB, 30 dB, 40 dB, preselection on,
        span/RBW<100, 95% confidence level, +200C to +300C

        • 9 kHz ≤ f < 3.6 GHz:  0.46 dB
        •  3.6 GHz ≤ f ≤ 7 GHz:  0.57 dB

Calibration

Standard calibration with a 90-day warranty included. Please contact us for additional calibration service prices.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

NIST-Traceable Calibrations

Standard Calibration Price (without data): Request a Quote
ANSI Z540 Calibration Price (with as-found & as-left data): Request a Quote
ISO/IEC 17025:2005 Accredited Calibration Price (with data & uncertainties): Request a Quote
ANSI Z540.3 with data & uncertainties and Guardbanding: Request a Quote
Test & Measurement Equipment Repair Services: Request a Quote

*Note: Prices shown on the nscainc.com’s site do not include taxes or credit card fees. Prices do not include shipping and handling unless otherwise noted. Prices and product availability are subject to change without notice. All specials and promotions limited to stock on hand. Contact us for current prices.

Datasheet

1