Keysight (formerly Agilent T&M) 83205A Cellular Adapter
Manufacturer Keysight (formerly Agilent T&M)Description
Description
The HP 83205A Cellular Adapter is an accessory to the HP 8921A Cell Site Test Set. The Cellular Adapter and Test Set are connected together via front-panel and rear-panel cables and work together to form a Test System. The Cellular Adapter adds digital signal generation and analysis to the analog test capabilities of the Test Set.
83205A CDMA specifications:
- Signal generator
- Frequency range: 824 to 894 MHz
- Resolution: 1 Hz
- Output level range at Test Set RF IN/OUT: -19 dBm to -137 dBm
- Output level range at Test Set DUPLEX OUT: +4 dBm to -127 dBm
- Modulation
- Reverse Link Source Modulation: OQPSK per TIA IS-95
- Reverse Link Source Modulation Data: Internal data buffer, Idle (all zeroes)
- Forward Link Source Modulation: QPSK per TIA IS-95
- Forward Link Source Modulation Data: Internal (Pilot channel)
- Residual Rho (ρ): 0.96
- Carrier Feedthrough: -30dBc
- Adjacent Channel Noise: -45dBc
- PN Offset: Adjustable from 0 to 511 units (1 unit equals 64 chips)
- PN Offset Resolution: 0.0156 units (1 chip)
- Data buffer
- Size: 5400 frames
- Modes: Single, Continuous Looping, and Idle
- Coding: IS-95 CDMA full rate reverse link channel coding, interleaving, and spreading
- Long Code Mask: 42 zeros
- Input Data Rate: 9600 bps; 14,400 bps
- Data Source: For each rate set, 300 frames factory loaded, 1800 frames additional user definable data can be entered via HP-IB
- Analyzer
- Output level range at Test Set RF IN/OUT: -10 dBm to +48 dBm
- Output level range at Test Set ANT IN: -46 dBm to +17 dBm
- Input Frequency Range: 4 MHz to 1000 MHz
- Rho (ρ) Measurement Interval Range: 0.25 to 1.25 ms
- Rho (ρ) Measurement Range: 0.50 to 1.00
- Average power measurement
- Input Frequency Range: 30 MHz to 1000 MHz at RF IN/OUT only
- Measurement Period: 0.25 ms to 5 ms
- Measurement Bandwidth: Provides an accurate measure of the total power for signals within 2 MHz of the operating frequency. If other signals are present outside this frequency range, reduced measurement accuracy will result
- Maximum Input Level: 60 W continuous
- Measurement Range: 1 mW to 60 W continuous (0 to +48 dBm)
- Code domain analyzer
- Input Frequency Range: 4 MHz to 1000 MHz
- Input Level Range at Test Set RF IN/OUT: Input Level Range:-10 dBm to +48 dBm
- Input Level Range at Test Set ANT IN: Input Level Range: -46 dBm to +17 dBm
- Measurement Dynamic Range: 40 dB
- Measurement Resolution: 0.01 dB
83205A CDPD signal generator specifications: Some specifications (not shown below) are the same as for the 8921A Test Set. (The CDPD Analyzer frequency range and input level range are also the same as for the 8921A Test Set.)
- Spectral purity
- Spurious Signals, Adjacent Channels: <-26 dBc
- Spurious Signals, First Alternate Channel: <-45 dBc
- Spurious Signals, Second Alternate Channel: <-60 dBc
- Switching Speed: Typically <150 ms to be within 1 kHz
- Transmitter On/Off Level and Timing: >15 dB down in <1 ms
- Modulation Type: GMSK with BT = 0.5
NIST-Traceable Calibrations
Standard Calibration Price (without data): Request a Quote
ANSI Z540 Calibration Price (with as-found & as-left data): Request a Quote
ISO/IEC 17025:2005 Accredited Calibration Price (with data & uncertainties): Request a Quote
ANSI Z540.3 with data & uncertainties and Guardbanding: Request a Quote
Test & Measurement Equipment Repair Services: Request a Quote