Temperature Calibrations
Tra-Cal provides temperature calibration service for a broad range of thermometers including:
- Liquid-in-glass thermometers
- Bimetal and dial thermometers
- Thermocouples
- Resistance temperature detectors (RTDs)
| NIST-traceable report for: | Description |
|---|---|
| Temperature datalogger | Three test points across range |
| Temperature transducer/transmitter | 0.5°C (0.9°F) or worse accuracy |
| Better than 0.5°C (0.9°F) accuracy | |
| Handheld digital indicator | Four test points across range, –45° to 500°C (-49° to 932°F) |
| Scanning thermometer, meter only | Four temperature test points across range of instrument |
| Scanning thermometer, 12-channel | Four temperature test points with probes, –45° to 500°C (-49° to 932°F) |
| Simulation temperature to mV or Ω | |
| Scanning thermometer, 24-channel | Four temperature test points with probes, –45° to 500°C (-49° to 932°F) |
| Dry-well calibrator, single | Multiple test points across range of instrument, –45° to 500°C (-49° to 932°F) |
| Dry-well calibrator, dual | Multiple test points across range of instrument, –45° to 500°C (-49° to 932°F) |
| Thermometer, glass (liquid-in-glass) | One-point -49° to 572°F (–45 to 300°C) ERTCO enclosed thermometer |
| Two to four test points across range, –45° to 300°C (-49° to 572°F) | |
| Five to nine test points across range, –45° to 300°C (-49° to 572°F) | |
| Ten to fifteen test points across range, 45° to 300°C (-49° to 572°F) | |
| HART®-style PRT | Per manufacturer’s specifications |
| Temperature bath | Per manufacturer’s specifications |
Temperature Meter, Probe, and System Calibrations
For many types of thermometry probes your application requires, Tra-Cal can ensure the accuracy of your meter, probe, or system!
| NIST-traceable report for: | Description |
|---|---|
| Thermocouple, standard types | Four test points across range of instrument. Meter: –270 to 2316°C (–454 to 4200°F); Probe and System: –80 to 1300°C (–112 to 2372°F). Actual range is dependent on type of probe. |
| RTD | Four test points across range of instrument. Meter: –200 to 1000°C (–328 to 1832°F); Probe and System: –80 to 1300°C (–112 to 2372°F). Actual range is dependent on type of probe. |
| Bimetal or dial | Four test points across range, –197 to 1000°C (–320 to 1832°F) |
| PRT probe or HART® style meter and probe | Four test points across range of instrument. Meter: –270 to 2316°C (–454 to 4200°F); Probe and System: –80 to 1000°C (–112 to 1832°F). Actual range is dependent on type of probe. |
All Equipment is returned with a NIST-Traceable certification. Calibration services available:
- ANSI Z540 Standard without data
- ANSI Z540-1 with as-found & as-left data
- ISO/IEC 17025:2017 with data & uncertainties
- ANSI Z540.3 with data & uncertainties and Guardbanding
In addition to our Calibration services, Tra-Cal provides the following services for test equipment and instruments from major manufacturers:
- Maintenance
- Repair (including obsolete equipment!)
Advantages of Selecting Tra-Cal to Calibrate Your Precision Test and Measurement Instruments
- Provide repeatable accuracy, saving time, money, materials, and labor.
- Calibrating your precision test and measurement instruments is the easiest way to avoid errors.
- Meet regulatory compliance requirements
- Reduce the risk of products failing in service.
- Save money from warranty and rework costs.
Contact us to get a free quote on our Temperature Calibration Services today!