Skip to content
+1-888-280-6722 info@nscainc.com My Account
Temperature Calibration Services

Temperature Calibrations

Tra-Cal provides temperature calibration service for a broad range of thermometers including:

  • Liquid-in-glass thermometers
  • Bimetal and dial thermometers
  • Thermocouples
  • Resistance temperature detectors (RTDs)
NIST-traceable report for: Description
Temperature datalogger Three test points across range
Temperature  transducer/transmitter 0.5°C (0.9°F) or worse accuracy
Better than 0.5°C (0.9°F) accuracy
Handheld digital indicator Four test points across range, –45° to 500°C (-49° to 932°F)
Scanning thermometer, meter only Four temperature test points across range of instrument
Scanning thermometer, 12-channel Four temperature test points with probes, –45° to 500°C (-49° to 932°F)
Simulation temperature to mV or Ω
Scanning thermometer, 24-channel Four temperature test points with probes, –45° to 500°C (-49° to 932°F)
Dry-well calibrator, single Multiple test points across range of instrument, –45° to 500°C (-49° to 932°F)
Dry-well calibrator, dual Multiple test points across range of instrument, –45° to 500°C (-49° to 932°F)
Thermometer, glass (liquid-in-glass) One-point -49° to 572°F (–45 to 300°C) ERTCO enclosed thermometer
Two to four test points across range, –45° to 300°C (-49° to 572°F)
Five to nine test points across range, –45° to 300°C (-49° to 572°F)
Ten to fifteen test points across range, 45° to 300°C (-49° to 572°F)
HART®-style PRT Per manufacturer’s specifications
Temperature bath Per manufacturer’s specifications

 

Temperature Meter, Probe, and System Calibrations

For many types of thermometry probes your application requires, Tra-Cal can ensure the accuracy of your meter, probe, or system!

NIST-traceable report for: Description
Thermocouple, standard types Four test points across range of instrument. Meter: –270 to 2316°C (–454 to 4200°F);
Probe and System: –80 to 1300°C (–112 to 2372°F). Actual range is dependent on type of probe.
RTD Four test points across range of instrument. Meter: –200 to 1000°C (–328 to 1832°F);
Probe and System: –80 to 1300°C (–112 to 2372°F). Actual range is dependent on type of probe.
Bimetal or dial Four test points across range, –197 to 1000°C (–320 to 1832°F)
PRT probe or HART® style meter and probe Four test points across range of instrument. Meter: –270 to 2316°C (–454 to 4200°F);
Probe and System: –80 to 1000°C (–112 to 1832°F). Actual range is dependent on type of probe.

 

All Equipment is returned with a NIST-Traceable certification. Calibration services available:

  • ANSI Z540 Standard without data
  • ANSI Z540-1 with as-found & as-left data
  • ISO/IEC 17025:2017 with data & uncertainties
  • ANSI Z540.3 with data & uncertainties and Guardbanding

 

In addition to our Calibration services, Tra-Cal provides the following services for test equipment and instruments from major manufacturers:

  • Maintenance
  • Repair (including obsolete equipment!)

 

Advantages of Selecting Tra-Cal to Calibrate Your Precision Test and Measurement Instruments

  • Provide repeatable accuracy, saving time, money, materials, and labor.
  • Calibrating your precision test and measurement instruments is the easiest way to avoid errors.
  • Meet regulatory compliance requirements
  • Reduce the risk of products failing in service.
  • Save money from warranty and rework costs.

 

Contact us to get a free quote on our Temperature Calibration Services today!

Request a Quote