Skip to content
+1-888-280-6722 info@nscainc.com My Account

Megger® 230315 Hi-Pot Tester

Manufacturer Megger®
Category: Brand:

Description

Description

Megger 230315 3 kV AC High-Pot Tester is designed for safety and ease of operation, and readily adapt to development, maintenance or production testing. It features a front-panel, NEMA 5-15R three-prong output receptacle. Booted, alligator-clip output and return probes are also supplied with Megger 230315.Test voltage is continuously adjustable from zero to full output, with a zero-start interlock. Leakage current trip level may be adjusted from 0.3 to 12 mA by a front-panel knob. Pushbuttons are provided to select one-second or continuous testing, to turn off the high voltage and to reset the instrument. All high-voltage connections are recessed to prevent accidental contact with high voltage.

Key Features

  • Ground continuity check of three-wire devices with high-voltage interlock
  • Front-panel adjustable leakage current trip from 0.3 to 12 mA
  • One-second or continuous testing
  • Automatic failure shutdown, with visual and audible alarms
  • Recessed high-voltage connections
  • Front-panel NEMA 5-15R three-prong receptacle
  • Zero start/reset in event of failure
  • Meets UL 120-k½ requirement

NIST-Traceable Calibrations

Standard Calibration Price (without data): Request a Quote
ANSI Z540 Calibration Price (with as-found & as-left data): Request a Quote
ISO/IEC 17025:2005 Accredited Calibration Price (with data & uncertainties): Request a Quote
ANSI Z540.3 with data & uncertainties and Guardbanding: Request a Quote
Test & Measurement Equipment Repair Services: Request a Quote