Agilent 86100 Wideband Oscilloscope
(Communication Analyzer)
General Description:
NSCA is proud to offer Agilent’s 86100C, as a used
refurbished instrument, complete with warranty and Calibration to Full OEM
specification. This instrument is a
comprehensive multi-function communication analyzer for high-speed electrical
and optical signals.
Agilent’s 86100C Infiniium
DCA-J combines high accuracy and repeatability with ease of use to simplify
characterizing signals from 50 MHz to 80GHz. Digital designers can combine the
mainframe and modules into four key instruments with high signal integrity
performance, including:
Ø A Full Function Oscilloscope to 80GHz
Ø A Digital Communications Analyzer
Ø Jitter and Interface Analyzer
Ø A Full Function TDR
Advanced Analysis Features:
Advanced Jitter Analysis
Ø Decomposition of jitter into Total Jitter (TJ), Random
Jitter (RJ), Deterministic Jitter (DJ), Periodic Jitter (PJ), Data Dependent
Jitter (DDJ), Duty Cycle Distortion (DCD), and Jitter induced by Intersymbol Interference (ISI)
Ø Jitter frequency spectrum
Ø Isolation and analysis of Sub-Rate Jitter (SRJ), that
is, periodic jitter that is at an integer sub-rate of the bitrate
Ø Jitter spectrum/phase noise for both clock or data
signals (requires 83496B Clock Recovery)
Ø Decomposition of interference into Total Interference
(TI), Random Noise (RN), Deterministic Interference, Periodic Interference
(PI), and Inter-symbol Interference (ISI)
Advanced Amplitude
Analysis
Ø Tabular and graphical results for both one and zero
levels
Ø Interference frequency spectrum
Ø Q-factor (isolated from deterministic interference)
Ø Relative Intensity Noise (RIN 1 Level, RIN OMA)
Advanced Waveform
Analysis
Ø Accurately capture long waveforms (up to 223 bits)
with or without averaging
Ø Samples/waveform limited only by size of hard disk or
memory stick
Ø Oscilloscope measurements on equalized waveforms with
built-in Linear Feedforward Equalization (LFE) tool
Ø MATLAB® (a registered trademark of The Mathworks Inc) interface allows instant processing of
oscilloscope data:
Ø Observe and characterize the output waveforms of any
LFE, Decision Feedback Equalizer (DFE) or other algorithm
Ø Calculate and display figures of merit or penalty
using proprietary or published scripts, such as Transmitter Waveform Dispersion
Penalty (TWDP)
Advanced TDR Analysis
(Frequency-Domain S-Parameters)
Ø On-board S-parameters for differential or single-ended
characterization
Ø One port or two port devices (single-ended or
differential)
Ø Measure to current and new standards
Product Specification/Details:
86100C DCA-J -
Oscilloscope Mode
Ø Electrical bandwidth from 12 to over
80 GHz ensure the most precise waveforms and pulse fidelity.
Ø Probing - if connectorized
test points are not available, use the Infiniimax
probes to your advantage by pairing them with the N1022A probe adapter and the
DCA-J's wide bandwidth inputs.
Ø Pattern Lock enables single-valued waveform viewing at
even the fastest bit rates when no separate pattern or frame trigger is
available.
Ø Even closed eyes can be captured as pulse train data
and the effectiveness of common equalization schemes are seen from on-board
algorithms.
86100C DCA-J - Eye/Mask
Mode
A digital
communications analyzer with automated eye diagram analysis for transmitter
compliance testing.
Eye diagram analysis is the easiest and most intuitive
method for viewing high-speed digital communications waveforms. The 86100C has
the capability to view both optical and electrical digital communications
signals.
Ø Built-in industry standard optical reference receivers
for rates from 155 Mb/s to 11 Gb/s
Ø Optical bandwidths to over 65 GHz for the most
accurate waveform fidelity
Ø Most precise extinction ratio measurements
Ø Pattern Lock isolates bit sequences leading to mask
violations and allows averaging to view noise-impaired signals
Ø Built-in equalization for analysis of dispersion
limited signals and equalization verification
86100C DCA-J - Jitter
Mode
The 86100C can perform accurate jitter analyzer
measuring subcomponent jitter sources with one-button ease of use. Accurate jitter analysis, including decomposition of
jitter into its constituent components, is becoming critical as data rates
increase. Decomposition provides critical insight for jitter budgeting and
performance optimization in device and systems designs. Jitter Mode decomposes
jitter into its constituent components and presents jitter data in various
insightful displays. Jitter Mode operates at all data rates the 86100C
supports, removing the traditional data rate limitations from complex jitter
analysis.
The Advanced Jitter Analysis - Option 200, provides:
Ø Decomposition of jitter into Total Jitter (TJ), Random
Jitter (RJ), Deterministic Jitter (DJ), Periodic Jitter (PJ), Data Dependent
Jitter (DDJ), Duty Cycle Distortion (DCD), and Jitter induced by Intersymbol Interference (ISI)
Ø Various graphical and tabular displays of jitter data
Ø Export of jitter data to convenient delimited text
format
Ø Save/Recall of jitter database
Ø Jitter frequency spectrum
Ø Isolation and analysis of Sub-Rate Jitter (SRJ), that
is, periodic jitter that is at an integer sub-rate of the bitrate
Ø Bathtub curve display
Related Applications
Ø Fibre Channel
Ø PCI Express
Ø FBD
Ø SATA
Ø SAS
Ø Infiniband
Ø IEEE 802.3ae
Detailed
Specification Data Sheet – Click Here for PDF
Related Images:
Ø 86100C Histogram Mode (Click for Image)
Ø 86100C TDR Mode (Click for Image)
Ø 86100C Eye Mode (Click for
Image)
Ø 86100C Oscilloscope Mode
(Click for Image)
Related Product Links:
(Similar
Mainframe) Agilent HP 83480A Mainframe – Click Here
(Similar Standalone
Product) Agilent HP 54750A
(Predecessor
Mainframe) Agilent HP 86100A
(Predecessor
Mainframe) Agilent HP 86100B